Konica 50kW U-Arm Orthopedic X-Ray
(Other kW options available) Can be combined with the DR solution best fit for your practice.
Motorized Swivel Arm with Flat Panel Cabinet
Floor-to-wall mounted support with fully motorized “U” arm for all movements. Dual Speed enables effortless and accurate settings with electromagnetic brakes for all movements.
Easy Positioning and User-Friendliness
Positioning control for all movements is available from the tube/collimator head, enabling control of SID, system height, angulations for the swivel arm and detector, plus two automatic positioning buttons for chest and under table positioning. Unlimited programs are available for auto-positioning of the most common studies from the flat panel LCD 10″ color control display located on the stand. Auto Position Programming enables positioning with the push of a single button after selection of the program while with the patient.
The system (via the 10″ flat display) is able to control generator exposure parameters, enabling presetting or modification of parameters by the technician while at patient-side, before leaving to make the exposure. As the digital imaging system is fully integrated with the URS system, pre-programmed anatomical (APR) exposure techniques are synchronized with the system stand, moving the system to the corresponding position required for your study. The generator operator control console APR has been pre-programmed with the exposure parameters for various common types of study (kVp, mA, mAs and time) and mechanical position (SID, Angulations of arm and detector, height of system and collimation in case of having autocollimator) for each study, enabling auto positioning of the system with a single button.
Security Systems
Volumetric control depending on the characteristics of the room, in order to avoid possible collisions during the system positioning–anti-collision pressure sensor during the movement of the system, along the Swivel portion of the arm. Double Photocell system: One at the Start of the “U” arm area which automatically changes the speed of the system to “slow motion”, reducing the risk of harm to patient when positioned inside the arm arch. The second is located close to the end of the “U” arm area and serves to automatically “block” the system to avoid any harm or fear to the patient.
Mechanical Movements
Manual Collimator
Three Phase High Frequency Generator SHF525 50kW/150kV Anatomical Program Microprocessor Controlled
High/Low Starter (3000/10,000 RPM) for one X-Ray tube
X-Ray Tube, Toshiba Model E7254FX
Standard Radiographic Moving Table with brakes in two wheels; laminated structures of high compression.
* These fields are required.
Call Us Today TOLL FREE
We have been in business since 2003. We started with selling only a handful of products and now sell over 3,000 products and have thousands of installations nationwide.
© 2021 Dicom Solutions | All Rights Reserved | Created by DEGOM Marketing